Fault isolation of depth acquistion problem associated with a depth sounding product

$
0
0
In the absence of an EDI transducer tester (relatively few marine electronics installers are so equipped), fault isolation of problems associated with a depth sounding product are typically accomplished by testing the depth sounding product with another compatible transducer which was known to be operational. In many cases, it is quite cost effective and more convenient for the customer to perform such fault isolation, as the cost of another compatible transducer may be close to or less than the cost of having a Certified Raymarine Installer visit the vessel to perform such fault isolation.

Transducers used for such testing are either suspended over the side of the hull or, in the case of non-cored fiberglass hulls less than one inch thick, placed on the inside of the hull atop a zipper locking plastic bag which has been completely filled with water. When performing such testing, the vessel must be located in water which is at least three feet in depth below the transducer, but not in a depth exceeding the maximum depth capability of the depth sounding product. Should the depth sounding product fitted with the test transducer be capable of reliably reporting depth using each of its supported frequency settings, then the currently installed transducer would be deemed to have been the cause of the depth related failure. However, should the depth sounding product fitted with the test transducer not be capable of reliably reporting depth using each of its supported frequency settings, then the fault may be rooted in both the transducer and/or the depth sounding product. Some EDI transducer testers are also capable simulating the output of a transducer to permit the depth sounding product to be tested. In the case of the latter, it would be recommended that the depth sounding product (if still supported) be sent to Raymarine’s Product Repair Center to be bench checked / serviced.


CRAFAQ#

Viewing all articles
Browse latest Browse all 8621

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>